Chapter 77 The Biophysical Profile Margaret A. Dahmus and Erol Amon Table Of Contents | |
Margaret A. Dahmus, MD Erol Amon, MD |
INTRODUCTION |
In the past 20 years, much information about normal and abnormal fetal behavior has been discovered through clinical and basic science research. These observations have aided the development of antenatal tests to distinguish healthy fetuses from potentially compromised fetuses. The primary goals of antenatal surveillance programs are ultimately to decrease perinatal morbidity and mortality. In the United States, 7.71 fetal deaths and 6.31,2 neonatal deaths per 1000 live births occur annually. Until relatively recently, the nonstress test (NST) and contraction stress test (CST) were the primary methods available for fetal surveillance. Reassuring tests are highly predictive of a healthy, nonasphyxiated newborn.3 Unfortunately, abnormal test results are poorly predictive of an asphyxiated newborn. In fact, the false-positive rate of both tests is greater than 50%.3 Combination testing with an NST and real-time ultrasonographic assessment of certain fetal parameters has been used since the late 1970s. This combination testing is called the biophysical profile (BPP). It includes both acute markers of fetal status (fetal heart rate reactivity [FHR-R], fetal breathing [FB] movements, fetal gross body movements [FM], and fetal tone [FT]) and some chronic markers of the fetal and intrauterine condition (amniotic fluid volume [AFV] and, in one form of the BPP, placental grading, too). The BPP may be considered a type of intrauterine Apgar score, and it may predict neonatal acidosis at delivery better than the Apgar score.4 Clinical applications, efficacy, and management protocols for different clinical situations are discussed in this chapter. |
THE GRADUAL HYPOXIA MODEL | ||||||||||||||||
Fetal biophysical activities such as FB, FM, and FHR-R are not random events but are controlled by specific centers within the central nervous system (CNS). Because normal fetal neurodevelopment requires increasing oxygen availability, the presence of such complex biophysical activities indicates a functioning, nonhypoxemic CNS. The lack of normal biophysical activity may be due to hypoxia, reflecting a comatose state. However, an abnormal score may occur in a healthy fetus in the resting phase of a normal sleep-wake cycle. Fetal activity cycles may be short term (20 to 80 min) or long term (diurnal). Individual CNS centers that may regulate the biophysical activities appear to vary in their sensitivity to hypoxia. Accordingly, a “gradual hypoxia” model has been proposed in which the activities that first appear embryologically are the last to disappear with progressively worsening hypoxia.4,5 Table 1 shows the postulated neurodevelopmental sequence of acquisition of fetal biophysical activities. For example, the first activity to appear, FT, at about 7.5 to 8.5 weeks, is also presumably the last activity to disappear with progressively worsening hypoxia.6,7 FM allegedly develops after FT (at 9 weeks),7 then FB (at 20 to 21 weeks),7 and finally FHR-R, at approximately 28 weeks.8 According to the gradual hypoxia model, FHR-R should be the first component of the BPP to become abnormal (i.e., to be lost) in hypoxic states. The gradual hypoxia concept would help explain the increased incidence of abnormal outcome as more biophysical activities decrease in occurrence and eventually disappear. Ultimately, the persistent and true lack of FT should be associated with the highest perinatal death rate. TABLE 1. Proposed Fetal Central Nervous System Centers
Hypoxia can cause acute and chronic fetal effects. The BPP measures some acute fetal characteristics that can be affected by hypoxia (i.e., FB, FM, FT, and FHR-R) and some chronic characteristics that can show effects of prolonged hypoxia (i.e., decreased AFV and, in Vintzileos' BPP methodology, a grade 3 placenta). Presumably, progressively worsening hypoxia causes increasingly more of the measured biophysical variables to become abnormally decreased in frequency or entirely absent. The composite BPP score may thus, in many circumstances but not all, provide a noninvasive estimation of the degree of fetal acidemia. Vintzileos and colleagues correlated BPP scores with umbilical cord blood gases in 124 nonlaboring patients, within 6 hours of cesarean delivery.9 Twenty fetuses were acidotic (cord arterial pH < 7.20). They found that FHR-R and FB were the first two activities inhibited by fetal acidosis. If an abnormal BPP was equated with the absence of only these two components, the test had 100% sensitivity, 92% specificity, 71% positive predictive value (PPV), and 100% negative predictive value (NPV) for an acidotic umbilical arterial pH. FM movement and FT began to decrease as pH decreased to a value between 7.10 and 7.20, and these activities were absent at a pH less than 7.10. Ribbert and co-workers studied 14 fetuses with severe intrauterine growth retardation (IUGR) from 25 to 39 weeks' gestation using BPPs followed by cordocentesis.10 They calculated the difference between the umbilical venous pH values in these fetuses and those of appropriately grown fetuses of the same gestational age. They found a significant correlation (r = 0.84, p < 0.001) between the total BPP score and this calculated umbilical venous pH difference. No correlation was noted between the BPP score and the similarly calculated differences in umbilical venous oxygen tension, carbon dioxide tension, oxygen saturation, or hemoglobin concentration. Seven of the 14 BPPs were abnormal (<8). In agreement with Vintzileos,9 Ribbert and associates10 found that FHR-R and FB were the first components to become abnormal and FM and FT were the last components to become abnormal. They postulated that the BPP score can predict fetal acidemia, but close attention should be given to the individual components of the BPP. In contrast, Manning and collaborators were unable to find an obvious sequential loss of biophysical activities in a larger study of 525 fetuses with an abnormal BPP within 48 hours of delivery.11 The appropriate clinical interpretation of a definite hypoxic threshold for different fetal activities is controversial and requires more study. Because the fetal behavioral characteristics measured by the BPP develop at different gestational ages, age-related interpretation of BPP results is necessary in very young fetuses. A description of each BPP component follows. |
COMPONENTS OF THE BIOPHYSICAL PROFILE | ||||||||||||||||||||||||||||||||||||||||
Fetal Heart Rate Reactivity A fetus with an intact, functioning CNS should have fetal heart rate (FHR) accelerations during movement.12 However, healthy fetuses may require 80 minutes to demonstrate FHR-R, presumably because of prolonged normal sleep-wake cycles.13 As noted previously, FHR-R develops at approximately 28 weeks.8 Castillo and colleagues studied 30 normal fetuses every 2 weeks from 24 to 32 weeks' gestation and found a trend of increasing reactivity with increasing gestational age. 14 Defining FHR-R as three accelerations of 15 beats per minute (bpm) lasting 15 seconds in 30 minutes, they found that the incidence of nonreactive NSTs (NR-NSTs) decreased from 50% at 24 weeks' gestational age to 6.7% at 32 weeks. Other investigators have also noted increased FHR-R with increasing gestational age.15,16,17 Castillo and associates also found that they could decrease the incidence of NR-NSTs by increasing the testing time from 30 to 90 minutes. After 90 minutes, only 6.7% of NSTs were nonreactive at 24 weeks, whereas 50% were nonreactive after 30 minutes. Likewise, at 30 minutes, 6.7% of the NSTs were nonreactive at 32 weeks' gestation, but only 3.3% were still nonreactive after 90 minutes. Thus, it is reasonable to extend the NST testing period in fetuses less than 32 weeks. Finally, Castillo and co-workers found that by defining FHR-R as three accelerations of 10 bpm (instead of 15 bpm), all fetuses greater than or equal to 26 weeks' gestation were reactive by the end of 60 minutes, and 87% of the 24-week fetuses were reactive. However, before this particular modified definition of FHR-R can be used routinely, more evaluation is necessary. By provoking FHR accelerations, vibratory acoustic stimulation (VAS) may decrease the number of false-positive NST responses and decrease testing time.18,19 VAS-induced FHR accelerations may be highly predictive of the absence of acidosis.20 Several investigators have noted predominantly nonacidotic fetal scalp or umbilical arterial cord pH values after a reactive FHR response to VAS. These studies also show that a nonreactive FHR response after VAS does not necessarily signify acidosis. Fetal Breathing Movements Prostaglandin E2 (PGE2) is probably the one parameter most inversely correlated with the incidence of FB.24 Prostaglandin synthetase inhibitors predictably increase and exaggerate FB, whereas PGE2 infusions directly into an experimental fetus inhibit FB after a graduated dose-response mechanism. Most basic investigators believe that PGE2 is intimately related to FB activity.24 Clinical studies relating to labor support this view.24 In fact, the BPP may well be unreliable for predicting fetal acid-base status during PGE2 application for cervical ripening in a human fetus.25 Although FB has been reported as early as 11 to 14 weeks with Ascan ultrasound techniques, it is not reliably noted until 20 weeks with real-time ultrasonography.26 Before that time, it is difficult to distinguish FB from generalized chest movements. Early FB is irregular but becomes more regular at midtrimester.27 During a 30-minute observation period, human FB incidence ranges from 0% to 98% during the day, with a mean of 30%.26,27,28,29,30 The average rate is 30 to 70 times per minute.27 Normal fetuses may have prolonged apnea, up to 108 minutes.31 The incidence of human FB may be affected by certain environmental agents or certain maternal states. There is some controversy in the literature about different agents' effects on FB. Some of the data reflect studies of small numbers of fetuses (Table 2).26–45 TABLE 2. Incidence of Fetal Breathing
ASSOCIATIONS OF FETAL BREATHING WITH PERINATAL OUTCOME. Platt and colleagues studied 136 pregnancies for the presence or absence of breathing in the last study before delivery.46 In 76% of cases, the study was conducted within 3 days of delivery. Low 5-minute Apgar (<7) scores were more frequent when FB was absent (50%) than when it was present (4%). Fetal distress in labor was significantly increased in fetuses with absent FB (60% versus 3% with FB present). Later, Manning and associates investigated the use of the NST and the FB component of the BPP in 223 high-risk pregnancies.47 Eighty-six percent of the tests were performed within 1 week of delivery. The predictive value of FB was similar to that of the NST for low 5-minute Apgar scores and intrapartum fetal distress. Tamura and Manning recommend evaluation of FB in those fetuses with a positive (but reactive) contraction stress test (CST) to help detect the fetuses destined to develop intrapartum fetal distress.30 Fetal Body Movement Hypoxic or otherwise compromised fetuses may not move as much as healthy fetuses, as confirmed by electromechanical detectors.48,49,50 Baskett studied fetuses at different gestational ages and found a similar incidence of FM from 28 weeks onward.17 He also noted that the number of abnormal responses on FM tests (i.e., decreased or absent FM) did not differ significantly between 26 weeks and term. Caffeine does not significantly change FM incidence.45 The effect of maternal glucose administration on FM is controversial.51,52 Cocaine intoxication may increase FM.53 Fetal Tone Baskett also found no significant difference in the proportion of abnormal results of tests of FT (<0.9%) between 26 weeks and term.17 Manning and co-workers found that when FT was absent on the last BPP before delivery, the incidence of fetal distress in labor, low 5-minute Apgar scores, and perinatal mortality were much higher than if FT was present.54 The BPPs were performed within 1 week of delivery. According to the gradual hypoxia model, FT is the last biophysical activity to be lost and should therefore be associated with the highest perinatal death rate. In a small study of 158 patients, Schifrin and associates found that absent FT (n = nine cases) correlated highly with poor outcome (in seven cases).55 In these seven poor-outcome cases, absent FT was also associated with a NR-NST, absent FB, and absent FM. In two cases of absent FT, normal outcome occurred, so the absence of FT cannot be absolutely equated with poor outcome. In both of these cases, the NST was reactive. A NR-NST and absent FT were the most efficient pair for prediction of poor outcome. Amniotic Fluid Volume In most cases, AFV does not reflect acute fetal CNS dysfunction. Nevertheless, decreased AFV is associated with increased perinatal morbidity and mortality.56 Clinical conditions associated with decreased AFV include IUGR, premature rupture of the membranes (PROM), postdatism, some major congenital anomalies, abdominal pregnancy, and excessive use of prostaglandin synthetase inhibitors.57 Decreased AFV may sometimes be due to hypoxia-induced reflex redistribution of cardiac output to the most vital organs, the heart and brain, with shunting of flow away from the amniotic fluid-producing organs, the kidneys and lungs.58,59 Two mechanisms help to explain the relationship of decreased AFV and perinatal morbidity and mortality. Decreased fluid may reflect utero-placental insufficiency, especially in growth-retarded and postdate fetuses.60 Second, the decreased fluid may increase the likelihood of umbilical cord compression and related sequelae. Manning and collaborators found an increased incidence of IUGR and perinatal mortality when the largest vertical pocket of amniotic fluid measured less than 1 cm.54 In a review of 7562 high-risk pregnancies, Chamberlain and associates found a sharp rise in perinatal asphyxia and mortality when severe oligohydramnios was present (largest vertical pocket 1 cm).56 Therefore, when the largest pocket of fluid measures less than 2 cm, they recommend careful consideration of delivery after attempting to rule out renal agenesis. In 336 patients, Phelan and colleagues found a statistically significant increased incidence of bradycardia, meconium, and cesarean section for fetal distress when the AFV was either “adequate but decreased” or “decreased.” 61 They defined decreased fluid as a pocket of fluid 1 cm or less within the uterine cavity. Adequate but decreased fluid was judged when a pocket greater than 1 cm was present but the sonographer subjectively believed that the AFV was decreased. In a further attempt to quantify AFV, Rutherford and co-workers developed a four-quadrant amniotic fluid index.62 The uterus is thought of as divided into four quadrants, and the largest vertical pocket of amniotic fluid in each quadrant is measured. These measurements are summed to give an amniotic fluid index. They found an increased incidence of meconium, fetal distress in labor, and low 5-minute Apgar scores in pregnancies with an amniotic fluid index of 5 or less. |
DEFINITION OF THE MAIN TYPES OF BIOPHYSICAL PROFILES | ||||||||||||||||||
Two general profiles for biophysical testing have developed. Manning and colleagues' protocol, first published in 1980, has been modified during the past decade.54 Vintzileos and associates' 1983 protocol remains unchanged.5 Additionally, several modified or abbreviated versions have been developed by others and are discussed later in the chapter. Manning has provided much of the literature on the clinical efficacy of the BPP. His testing profile involves five components: NST, FB, FM, FT, and AFV assessment. Each variable is graded 0 if absent or 2 if present, for a total score of 10. In Manning's initial test design, provision was made for an intermediate value of 1 should the data fit such a pattern. However, after further experience with the BPP, he determined that such additional descriptiveness was not justified. A normal score is 10, or 8 in the absence of oligohydramnios. An equivocal score is 6, and abnormal scores are 0, 2, or 4. In the initial study of 216 high-risk patients, Manning and collaborators found improved accuracy in predicting adverse perinatal outcome when a combination of biophysical parameters was measured instead of using only a single abnormal response.54 A BPP score of 10 (all tested parameters normal) was associated with a perinatal mortality rate of 0: 1000, whereas a BPP score of 0 (all variables abnormal) was associated with a 600:1000 perinatal mortality. Table 3 summarizes Manning's criteria for scoring the biophysical profile. TABLE 3. Biophysical Profile Scoring: Technique and Interpretation*
* Current “normal” amniotic fluid volume = Presence of pocket of fluid >2 cm in vertical distance56 † Current amniotic fluid volume measurement for “abnormal” score = largest vertical pocket 2 cm56. (Manning FA, Morrison I, Lange IR et al: Fetal assessment based on fetal biophysical profile scoring: Experience in 12,620 referred high-risk pregnancies. Am J Obstet Gynecol 151:345, 1985) Vintzileos and colleagues protocol5 is quite similar to the scoring system of Manning's group (Table 4). However, Vintzileos includes the placental grade as one of the BPP's components. This inclusion is based on data relating to an increased incidence of abnormal intrapartum fetal heart patterns and abruption in patients with a grade 3 placenta.5 Scores range from 0 to 1 to 2, with a total possible score of 12. An abnormal score is 7 or less. TABLE 4. Vintzileos' Criteria for Scoring the Biophysical Profile Nonstress test Score 2: 5 or more fetal heart rate accelerations of at least 15 bpm in
amplitude and at least 15 sec duration associated with fetal movements
in a 20-min period Fetal movements Score 2: At least 3 gross (trunk and limbs) episodes of fetal movements
within 30 min. Simultaneous limb and trunk movements were counted as
a single movement - Fetal breathing movements Score 2: At least 1 episode of fetal breathing of at least 60 sec duration
within a 30-min observation period - Fetal tone Score 2: At least 1 episode of extension of extremities with return to position of flexion, and also 1 episode of extension of spine with return to position of flexion Score 0: Extremities in extension. Fetal movements not followed by return to flexion. Open hand Amniotic fluid volume Score 2: Fluid evident throughout the uterine cavity . A pocket that measures 2 cm
or more in vertical diameter Placental grading Score 2: Placental grading 0, 1, or 2 Maximal score 12; minimal score 0 (Vintzileos AM, Campbell WA, Nochimson DJ, Weinbaum PJ: The use of real-time scanning in antepartum fetal evaluation: The fetal biophysical profile. In Sanders RC, Hill MC (eds): Ultrasound Annual, p 257. New York, Raven Press, 1985) Manning's scoring system is generally easier than that of Vintzileos and has received wider acceptance. Three important changes in Manning's profile have occurred since 1980. First, a normal score for FB requires 30 seconds of FB instead of the original 60 seconds. Second, the definition of oligohydramnios has changed. As of 1983, oligohydramnios is present when the largest vertical amniotic fluid pocket is 2 cm or less instead of less than 1 cm.56 Third, as of 1984, the NST is performed only if one of the dynamic ultrasono-graphically evaluated variables is abnormal.63 This third modification is discussed later in this chapter. Although equal weight is given to each component in Manning's BPP, in 1990, he and his coworkers reported that not all compositions of low BPP scores are clinically equivalent or equally distributed. This conclusion was made after reviewing the results of a decade of experience with the BPP.64 The PPV of a particular BPP score (i.e., such as for a score of 6) depends on the specific individual variables composing the score. For example, Manning found that the PPV for perinatal death with a BPP of 6 is significantly higher when the NST is nonreactive and FT is absent (370 : 1000) than when AFV and FB are absent (0 : 1000). Ten possible combinations of variables can give rise to a BPP score of 6, yet the distribution of observed combinations by frequency is not uniform. A scoring system with differential component weighting, although perhaps more accurate, would require considerable additional clinical evaluation for development. Nevertheless, Manning's testing results include the lowest perinatal mortality rate ever reported in the medical literature.64 Modified Protocols Using receiver operating characteristic curve (ROC) analysis, Richardson and co-workers (1985) analyzed Manning's early (1980) BPP studies.65 They could not demonstrate a benefit to multiparameter assessment in identifying a compromised fetus. The NST and FB were as predictive as the total profile score. In 1983, Vintzileos and colleagues found that a NR-NST was less helpful than the absence of FB and FM in predicting poor perinatal outcome.5 Applying Richardson's analysis and Vintzileos' findings, Shah and associates (1988) developed a protocol using ultra-sonographic assessment alone (no NST). with an expanded scale for FB and FM.66 Fundamental to this protocol, only a qualitative assessment of the more chronic parameters (AFV and placental grade) was performed. Because FT should be the last fetal behavior to become abnormal in the gradual hypoxia model, Shah and co-workers thought its absence might also reflect a more chronic type of stress. As such, it was only qualitatively evaluated. In the initial phase of the study, 172 patients had 303 tests that were scored according to both Vintzileos' method and the modified method. The results were highly correlated. In the second phase of this study, 180 patients were serially tested. The length of time between the last study and delivery was not noted in the article. Using FM, the NPV for fetal distress was 90.6% and for fetal death was 99.37%. Using FB alone, the NPV for fetal distress in labor was 92% and for fetal death was 100%. The PPVs for fetal distress and fetal death were 25% or less using either FM or FB. They proposed that assessment of acute fetal events-namely, FM and FB-could be used as an independent test, excluding the use of the NST. Thus, discriminative power would not be affected while saving time for busy clinicians. Because of the small number of patients studied and the lack of confirmatory studies, this modification has not been widely accepted. Devoe and co-workers (1988) criticized the arbitrary scoring system of the BPP, which gives equal weight and independence of each measured parameter.67 Furthermore, they believed that insufficient time was alotted for adequate fetal assessment in the conventional BPP and that important information was potentially lost when the NST was performed separately from the sonographic assessment. Finally, they believed that the frequency of observed behaviors (i.e., movement, breathing, and others) should be compared with those expected for fetuses of the same gestational age. Using a computerized analytic system, they simultaneously obtained FHR and biophysical information on 181 near-term fetuses that were delivered within 1 week of testing. Devoe's testing protocol is slightly different from those of Manning and Vintzileos in that a reactive NST requires at least three accelerations exceeding 15 bpm lasting 15 seconds within 30 minutes, and normal AFV requires at least two pockets with at least 1 × 1-cm dimensions. Devoe compared the observed biophysical results with standard nomograms. A test result was considered abnormal if the frequency of two or more tested components fell more than two standard deviations below the population's mean. Poor-outcome categories included fetal distress, 5-minute Apgar score less than 7, IUGR, and perinatal mortality. Test sensitivity (86%), specificity (89%), PPV (75%), and NPV (93%) occurred when two or more variables were abnormal. All anomalous fetuses were identified. All perinatal deaths and 19 of 22 (86%) of the infants with IUGR were detected. Interestingly, although no fetuses were apneic for longer than 45 minutes, 15 were apneic for more than 30 minutes and would have been missed with the standard BPP regimens of Manning and Vintzileos. The average testing time (60 min) and the need for sophisticated analytic equipment and specially trained personnel will probably prevent widespread use of Devoe's methodology. In contrast to the detailed work of Devoe, Clark and associates (1989) emphasized clinically expedient antenatal testing.68 They advocated the use of VAS with the NST, plus a four-quadrant AFV assessment. During a 3-year period, Clark and collaborators performed 5973 such tests on 2628 singleton high-risk pregnancies. If an NST was non-reactive after 5 minutes, VAS was performed and repeated once more within 10 minutes, if necessary. Only 3.2% of the NSTs were nonreactive with this protocol, significantly lower than in other series, implying a decrease in the number of falsely positive NSTs.69,70 The average testing time was only 10 minutes, and fewer specialized personnel were needed to perform ultrasonographic studies than were needed with other BPP protocols. No unexpected fetal deaths occurred. The 3% intervention rate was similar to that of other series.71 Manning modified his original design to exclude the NST unless one or more of the dynamic ultra-sonographic components was abnormal.63 NSTs had to be performed in only 2.7% of 7851 tests in 2712 patients. The predictive accuracy of the NST and FB were equivalent in this study. In general, the acute biophysical variables (i.e., FHR-R[NST], FB, FM, FT) had interchangeable predictive values, with no obvious individual advantage if all or most were normal. AFV (a chronic stress marker) needs to be measured because of its increased predictive value of abnormal outcome in the general high-risk population and especially in certain high-risk groups, such as those with IUGR or postdates. Manning does not base fetal assessment on the NST and AFV alone, however, because a reactive NST and a normal AFV with such testing would be considered reassuring regardless of abnormalities of the other variables. Accordingly, if the NST and AFV were the only two variables present (a rare occurrence and combination), yielding a BPP score of 4, the risk of adverse outcome would still be increased. The PPV would be similar to a score of 6, but not that of a normal BPP score.64 Role of the Nonstress Test in the Biophysical Profile Because the, NST may be the most sensitive BPP variable to detect fetal hypoxia, some believe it should be retained.72 Because FB has been noted in some diabetic and postdate pregnancies even when fetal compromise was present, FB and the NST may not be interchangeable tests of fetal well-being.73 Additionally, the NST may show unsuspected spontaneous late decelerations, signaling fetal hypoxia. Furthermore, some investigators advocate continued use of the NST to detect variable decelerations, which may be associated with adverse perinatal outcome even with normal AFV.74,75,76,77 Brioschi and colleagues reviewed 1552 NSTs performed within a week of delivery and found that even if the NST was reactive, baseline abnormalities or decelerations or both were associated with significantly increased perinatal morbidity and mortality.78 Smith and co-workers reviewed 8 years of NST experience, which included 38,645 tests in 14,028 patients.79 During this time period (January of 1978 to December of 1985), 65 fetal deaths occurred. Forty-seven of these patients had a reactive NST in the last testing session before delivery. Thirty-seven of the deaths occurred within 7 days of a reactive NST, and the other 10 occurred between 8 and II days after a reactive NST. Autopsies were performed on 53 of the stillborn infants, and 12 of them had abnormal umbilical cord positions (usually nuchal). Variable decelerations were noted in 5 of these 12 cases during the last NST. In four of the six stillbirths in their series of 583 postdate pregnancies, Eden and associates found variable decelerations during the last NST before delivery.80 All of the stillbirths occurred within 3 to 5 days of a reactive NST. There were no anomalies. Miyazaki and Miyazaki also noted that variable decelerations were more common in compromised postdate fetuses, even if the NST was reactive.81 Other investigators have not noted an increased risk of fetal distress or death with variable decelerations and worry that undue attention to them will lead to inappropriate intervention.82,83 Data on the predictive importance of variable decelerations are conflicting. However, sufficient evidence exists to compel further investigation of this FHR finding, which is only available through testing with the NST. In summary, several investigators have modified the original BPP protocols in order to decrease testing time or improve adverse outcome predictability. The ultimate adverse perinatal outcome, death, is sufficiently rare that possibly only Manning's initial BPP protocol (which included the NST) has been sufficiently tested and proved reliable in assessing fetal well-being. Additional studies with the modified protocols previously described are needed before major changes in BPP protocols become widely adopted. |
BIOPHYSICAL PROFILE IN SPECIFIC MATERNAL CONDITIONS |
Labor In a prospective, blinded study, Sassoon and colleagues monitored 95 patients (all singleton pregnancies at 36 to 42 weeks) with BPPs throughout labor.84 The initial BPP was performed at admission, before epidural anesthesia or rupture of the membranes. Scored by Manning's criteria (10 possible points), 75% of the patients had an initial normal score ( 8) but only 55% had a normal BPP on the final test. The frequency of both FB and FM decreased during labor. The decrease in FB contributed the most to the decreasing BPP score. Perhaps the CNS state is changed in labor, possibly as a result of the changing prostaglandin levels, and FB is thereby altered. The AFV remained constant during labor, even when rupture of the membranes occurred, measured either as the largest pocket or as an amniotic fluid index. None of the fetuses had absent tone, and the incidence of FHR-R did not change during labor. Additionally, as opposed to Vintzileos and colleagues' data in nonlaboring patients,9 Sassoon and co-workers found no correlation between the last BPP and the umbilical cord pH in these laboring patients. Normal BPPs ( 8) were not significantly associated with a pH greater than 7.20, and abnormal test results ( 6) were not significantly associated with an arterial pH less than 7.20, with a pH less than 7.15, or with metabolic acidemia. Half of the fetuses with a pH of 7.20 or less had a normal last BPP. Also, there was no significant difference in the BPP scores between the acidemic and nonacidemic fetuses. The mean time between the last BPP and delivery was 1.8 hours (range 0.5 to 5.6 hr) for the acidemic group and 3.9 hours (range 0.5 to 13.5 hr) for the nonacidemic group. The FHR tracing associated with the last BPP was similar to the other intrapartum tracings. No birth trauma occurred. A NR-NST was the only BPP parameter that correlated significantly with neonatal acidemia. None of the other BPP parameters increased its predictive ability for fetal acidemia. Interestingly, and in contrast to Vintzileos' results, the presence of FB on the last BPP was significantly associated with fetal metabolic acidemia. The BPP during cervical ripening with prostaglandin E2, before induction of labor by Amon and collaborators, shows that FB is virtually absent and that FM decreases, although FHR-R does not change.25 In summary, there are few studies correlating the intrapartum BPP with the resultant umbilical arterial (or venous) acid-base status. In contrast to the antepartum state, the BPP is not a reliable predictive test for acid-base status during the intrapartum state, nor during cervical ripening with prostaglandin E: immediately before oxytocin induction of labor. Postdate Pregnancy Johnson and associates evaluated semiweekly BPPs in 293 postdate pregnancies (defined as > 294 days from the last menstrual period).85 No perinatal deaths occurred if the BPP and AFV were normal. Additionally, fetal distress (3.3%) and 5-minute Apgar scores less than 7 (1.9%) were infrequent. However, if the BPP was abnormal or oligohydramnios (defined as the largest pocket of fluid < 1 cm) was present (N = 32), a significantly increased incidence of cesarean section for fetal distress (22%), low 5-minute Apgar scores (12.5%), and neonatal morbidity (19%) occurred. Neonatal morbidity was defined as meconium aspiration resulting in neonatal intensive care unit (NICU) admission. The cesarean section rate in pregnancies “prophylactically” delivered for a gestational age of 294 days or greater (with no other indication) was 42% (N = 50), compared with a 15% rate in the 180 patients allowed to begin spontaneous labor. This percentage was similar to the 16.5% cesarean section rate of the hospital obstetric population. Johnson and colleagues postulated that the BPP might help differentiate a normal from a compromised fetus, aid delivery decisions in a postdate pregnancy, and prevent undue maternal morbidity as a result of unnecessary cesarean delivery. Interestingly, when compared with 6536 tests on term fetuses with normal outcomes, Baskett found that 1587 tests on postdate fetuses (42 to 44 wk gestation), which also had good outcomes, were significantly more likely to have a NR-NST, abnormal FB and FT, and decreased AFV.17 In a study of 583 postdate patients (> 42 wk), Eden and associates found less mortality and significantly decreased morbidity when a fetus was assessed with semiweekly NSTs with modified BPPs and weekly AFV evaluations. Delivery was performed for FHR decelerations, decreased AFV, or abnormal BPP scores.80 Perinatal outcomes were similar to those recorded using weekly CSTs in postdate patients, but in both testing schemes, intervention rates exceeded 25%. In summary, management of a postdate pregnancy in the presence of an unfavorable cervix remains controversial. Again, no definitive answers are forthcoming from the available BPP studies, but data support delivery for an abnormal BPP or oligohydramnios. Predicting Infection in Patients with Premature Rupture of Membranes Antenatal fetal surveillance in patients with PROM has been problematic. Contraction stress tests are contraindicated, and amniotic fluid cultures, even when obtainable, are not sufficiently predictive of fetal sepsis.86,87 Several investigators have studied patients with PROM to see if BPPs are predictive of infection. Vintzileos and associates studied 73 patients with PROM.44 Fifty-three patients received BPP profile testing within 24 hours of delivery, 15 within 24 to 48 hours of delivery, and the other 5 at least 48 hours before delivery (but the time was not specified). In these 73 patients, a normal BPP ( 8) was associated with a 2.7% incidence of infection, whereas an abnormal score ( 7) was associated with a 93.7% incidence of infection. The data were not analyzed separately for the different time intervals between testing and delivery. Increased fetal oxygen demands due to infection were postulated to cause adaptive (protective) CNS alterations in fetal biophysical activity, to decrease oxygen utilization. Interestingly, there was no significant difference between the umbilical cord pH values of the infected and noninfected patients with PROM. Vintzileos and co-workers then used the BPP to manage 73 consecutive patients with PROM.88 They then compared the outcomes (of the “study” group) with those of two historic control groups: 73 patients managed conservatively (the “control” group) and 73 patients managed with amniocentesis results (the “amniocentesis” group). Fetuses were delivered for a persistently low BPP ( 7 on two examinations, 2 hr apart, with no FB and a NR-NST). Antibiotics were not given to the mother until the umbilical cord was clamped. In the “study” group, 21 patients had a BPP of 7 or less. Only one of these pregnancies had culture-proven neonatal sepsis. In the “control” group, 18 had a BPP of 7 or less. Seven of these had culture-proven neonatal sepsis. No BPP data were provided for the “amniocentesis” group. The incidences of maternal and neonatal infection and low 5-minute Apgar scores were significantly less frequent in the BPP-managed patients than in those managed conservatively. Likewise, the incidence of neonatal sepsis was significantly less in the BPP-managed group than in the amniocentesis-managed group. Unfortunately, as Ohlsson and Wang observed, the PPVs for clinical chorioamnionitis (30.8%–60%) and for neonatal sepsis (30.8%–47.0%) were too low to guide clinical decision making.89 Kivikoski and co-workers studied the effect of PROM in 44 pregnancies, 13 of which were eventually complicated either by amnionitis (N = 11), neonatal infection (N =1), or fetal distress (N = I) with spontaneous variable decelerations.40 The gestational ages ranged from 28 to 41 weeks. The remaining 31 “uncomplicated” cases of PROM were matched with 31 normal antepartum patients of similar gestational age. Exclusion criteria included labor, anomalous fetuses, and initial evidence of infection or fetal distress. FB presence required at least one episode lasting at least 60 seconds during a 30-minute observation period. All patients with PROM had an intravenous infusion containing 5% dextrose, whereas none of the control patients had any infusion. Because intravenous glucose can increase FB,32,33 the incidence of FB in the patients with PROM would have perhaps been even lower without the intravenous infusion. The incidence of FB was 90% in the 31 normal control patients and 65% in the 31 patients with uncomplicated PROM, a statistically significant difference (p < 0.05). In the 13 patients with complicated PROM, FB occurred in 38% of the cases, which was not significantly different (due to small numbers) from the 65% incidence in the 31 patients with uncomplicated PROM. The investigators hypothesized that the absence of FB might be due to PROM alone. Furthermore, although the presence of FHR-R and FB may be predictive of the absence of infection in patients with PROM, the absence of FB is not necessarily predictive of the presence of infection in patients with PROM. Goldstein and colleagues studied FB and FM in 41 cases of PROM.90 They found that 83% of the gestations with no fetal activity (no FM and no FB of > 30 sec duration during 30 min of observation) had a positive amniotic fluid culture. Conversely, none of the 17 gestations with an episode of fetal activity (defined in the same manner) had a positive amniotic fluid culture. When fetal activity was present, 90% (±3%) of the fetuses had negative amniotic fluid cultures for a least 48 hours. Therefore, the investigators believe that such complicated pregnancies can be monitored with biophysical testing every 48 hours when such fetal activity is present. Conversely, Miller and co-workers were unable to find any difference between the composite BPP or any of its components in 47 patients with PROM in predicting clinical chorioamnionitis.91 None of the mothers received antibiotics or corticosteroids. None of the neonares developed sepsis, preventing comparison with Vintzileos' previously published findings of lower BPP score correlation with neonatal sepsis.88 The workers acknowledge that a type 2 error (from the low incidence of chorioamnionitis) could have prevented detection of an association between the BPP and chorioamnionitis. In summary, in patients with PROM, the presence of normal fetal biophysical activities and a reactive NST is strongly associated with the absence of fetal infection. However, it is not known if the converse is true, because no large, well-designed study has been published to answer this question. In fact, the absence of FB during BPP examination may simply be due to uncomplicated PROM.40 Intrauterine Growth Retardation Ribbert and colleagues found close correlation of the BPP with umbilical venous pH from cordocentesis samples in a very small group of fetuses with severe IUGR.10 Of the 14 fetuses, 7 had an abnormal BPP ( 7). Like Vintzileos,8 Ribbert's group found that FHR-R and FB were the first biophysical activities to become abnormal with acidemia, and FM and FT were the last activities to disappear. The BPP correlated only with the umbilical venous pH, however, and not with the oxygen tension, carbon dioxide tension, or oxygen saturation. Manning and Hohler reviewed the utility of BPP testing in 960 cases of IUGR.92 The perinatal mortality rate (excluding anomalous fetuses) was only 12.5/1000, quite decreased from the expected rate of 60 to 80 deaths per 1000 in the population not receiving biophysical testing. From a practical viewpoint, when one is confronted with a fetus with IUGR, an etiologic workup is in order, and close fetal surveillance with ultrasonography is necessary. Because continuing sonographic surveillance for fetal malformation, oligohydramnios, fetal interval growth, and possible amniocentesis is important, one can justify the primary use of the BPP. It should still be recognized that twice-weekly testing of the fetus with a NST and once-weekly testing of AFV constitutes a reasonable alternative to twice-weekly BPP testing. Twin Gestations Using the BPP of Vintzileos and co-workers, Lodeiro and associates monitored 49 consecutive twin pregnancies with BPPs.93 Most patients received weekly tests, and the remainder underwent semiweekly testing. The last test occurred within 1 week of delivery. Sixty-four of the 98 NSTs (65%) were reactive, and 34.7% were nonreactive. A normal last BPP score of 8 or greater occurred in all fetuses with reactive NSTs. Sixty-two of these 64 fetuses had a good outcome. The remaining two fetuses (same pregnancy) developed chroioamnionitis and premature labor at 26 weeks gestation, 3 days after a reactive NST and normal BPP. Both died in the early neonatal period as a result of extreme prematurity. In 28 of the 34 cases with NR-NSTs, the BPP was 8 or greater. All of these had a good outcome. Fetal distress developed in the other six, but none died. In four twin pregnancies, all eight fetuses had NR-NSTs, but only one of each pair had an abnormal BPP and only that fetus developed fetal distress. The investigators recommend use of the BPP as a secondary backup evaluation of NR-NSTs. Nonetheless, fetuses with reactive NSTs still require sonographic fetal evaluation for interval growth, AFV, gender, real-formation, placentation, and development of by-drops throughout the antenatal period. Diabetes Mellitus Johnson and colleagues (1988) used the modified BPP protocol of Manning (real-time ultrasono-graphic evaluation of the four sonographic components with an NST only if one of the four parameters was abnormal) to monitor 238 well-controlled diabetic patients.94 Fifty insulin-dependent diabetic women and 188 gestational diabetic women were followed with semiweekly and weekly testing, respectively. Factors other than the BPP (not described in the article) were used to manage the patients as well. All insulin-dependent diabetic patients were delivered by 40 weeks, and all gestational diabetic patients by 42 weeks. Of the 230 patients with normal BPPs, 200 (87%) delivered at term with little maternal or fetal morbidity. Forty-five percent of all study patients had a vaginal delivery after spontaneous labor. The induction rate for the 230 patients was 32%, and the overall cesarean section rate was 23.9% (11.7% elective + 12.1% in labor). The BPP had a low sensitivity (22%) and PPV (37.5%) but high NPV (96.5%) for neonatal morbidity. Neonatal morbidity was defined as a 5-minute Apgar score less than 7 or NICU admission for a low 5-minute Apgar score, respiratory distress, congenital anomaly, or hypoglycemia. Seven of the 200 neonates had morbidity despite normal BPP scores (false-negative rate of 3.5%). No perinatal deaths occurred in structurally normal infants. The researchers recommend the use of the BPP weekly to aid delivery decisions in pregnant women with “normalized and uncomplicated” insulin-dependent and gestational diabetes. Dicker and collaborators monitored 98 insulin-dependent pregnant diabetic women with weekly BPPs after 28 weeks gestation.95 Results of only 28 (2.9%) of the 978 tests were abnormal (> 8 score). When the last BPP was performed within 2 days of delivery, the NPV (94.8%) and specificity (90.2%) were relatively high but the PPV (< 20%) was low for predicting intrapartum fetal distress. Similar findings for predicting a low 5-minute Apgar score were found, with a NPV of 98.7%, specificity of 87.3%, and PPV of 7.4%. For BPPs performed within 1 week of delivery, the NPVs for intrapartum fetal distress and for a low 5-minute Apgar score were similar to those obtained with semiweekly testing. The specificities were approximately 80% for each outcome, and very low PPVs of 17% occurred for each outcome. No perinatal deaths occurred, and the workers partially attributed this outcome to immediate intervention for abnormal scores. In summary, there are adequate data to support the use of the BPP in the management of pregnancy in diabetic women. However, the superiority of the BPP versus the NST as the primary means of fetal surveillance has not been shown. Sonographic surveillance of the fetus of a diabetic mother is necessary to assess for malformations, interval fetal growth, macrosomia, and AFV abnormalities. In well-controlled, compliant pregnant women with uncomplicated diabetes, fetal well-being testing may be performed weekly. Magnesium Sulfate Tocolysis In a study of 16 patients (6 twin and 10 singleton pregnancies) receiving magnesium sulfate tocolysis, Peaceman and colleagues found a significant decrease in FB and FHR-R causing a significant decrease in the BPP score.43 They suggested that these changes were due to the magnesium sulfate therapy. No significant effects on FT, FM, or AFV were found. The decreased FB was not thought to reflect changes associated with labor, because all but one fetus in premature labor exhibited FB on the initial admission BPP, before magnesium sulfate tocolysis was started. However, insufficient information about each patient's course (i.e., the rate and amount of cervical dilation, the dosage of magnesium sulfate required, and so on) was given to definitively negate the effect of labor on FB incidence. Detecting Congenital Anomalies Anomaly detection is a potential benefit of antenatal surveillance with the BPP. However, the ability to detect such anomalies is dependent on the skill of the sonographer. Anomaly detection was not successful in Platt and associates' series of 289 fetuses, because only 1 of 5 anomalous fetuses were detected before delivery with BPP testing.96 Some of these anomalies may have been difficult to detect even with specialized ultra-sonography, however. |
SPECIFIC MANAGEMENT PROTOCOLS FOR BIOPHYSICAL PROFILE TESTING |
After obtaining a BPP, the indications for intervention (i.e., delivery) vary only minimally between different investigators. In general, if a normal score is obtained, the testing is repeated weekly. Semiweekly testing is recommended for complicated diabetic pregnancies and for postdate pregnancies. However, in certain high-risk situations, depending on the physician's level of concern, daily testing (or more frequently) may be helpful. Specific management guidelines used by Manning and his group have been published.97,98 We recommend the following management scheme. The primary test for fetal surveillance of well-being is the NST. The reasons for this are that most clinicians are capable of performing and interpreting this test, expensive testing equipment and highly specialized personnel are unnecessary, and the negative (normal) predictive value is extremely reliable. AFV should be assessed weekly if there are known risk factors for oligohydramnios (e.g., IUGR, postdates, FHR variable decelerations). Either a subjective grading or an amniotic fluid index is sufficient. The frequency of testing depends on the degree of fetal risk and varies from daily to weekly. If the fetus has never had a late (> 20 wk) sonographic evaluation at the testing center, then at least a single complete fetal evaluation is recommended. If the primary test (the NST) is nonreactive or unsatisfactory (i.e., from conditions such as extreme obesity), the appropriate next test is the BPP, performed according to the method of Manning. In the absence of fetal structural or alloimmunized abnormalities and in the absence of obstetric (i.e., placenta previa, prior vertical uterine incision, postdate pregnancy with a favorable Bishop score) or maternal indications (i.e., pre-eclampsia, antecedent moderate to severe medical disease) for delivery, management may proceed according to the test results. Accordingly, if the results are normal (i.e., 8/10 with normal amniotic fluid, or 8/8), then continued fetal testing is indicated. If the results are equivocal (i.e., 6/10 with normal fluid), repeat testing within 24 hours is indicated to distinguish a fetus in a sleep cycle. If repeat results are normal, then continued testing is indicated. However, if the results are persistently 6/10 (with normal fluid) and the fetus is mature, delivery of the fetus is indicated. If this fetus is immature, however, close surveillance with frequent fetal testing is indicated. If abnormal testing is encountered (4), delivery is indicated in most cases. In the circumstance of an extremely premature fetus, intensive fetal surveillance with continuous monitoring may be safely used. In this setting, clinical consultation with maternal-fetal medicine is of utmost importance. Finally, if abnormal AFV is found in a patient with intact membranes with a score of 6/10 or 8/10, a determination of functioning renal parenchyma must be made. If functioning renal parenchyma is thought to be present and the fetus is mature, then delivery is indicated. In the situation remote from term, delivery is still generally indicated; however, consultation with maternal-fetal medicine may improve maternal and perinatal outcome. The use of the CST in our current practice is rare. If a spontaneous CST is observed, the results are noted and interpreted in light of other fetal test results. |
EFFICACY OF THE BIOPHYSICAL PROFILE |
In his early work (1980), Manning found that each component of the BPP had a false-positive rate approaching 50%, which he attributed to normal periodicity in most cases.54 The combination of the five components into one score improved the PPV and NPV. A contraction stress test was required only three times (0.25%) in the first 1184 high-risk patients for further fetal evaluation.99 Additionally, 13 of 19 major congenital anomalies were detected with ultrasonography in this same group. After reviewing the results of 26,257 BPPs, Manning found only one instance when an abnormal BPP (score of 4 out of a possible 10) reverted to normal.100 This particular fetus received severe head trauma when his mother's pelvis was fractured. Over 3 weeks, the BPP score became normal. At birth, the infant was not asphyxiated and survived. Using ROC analysis, Richardson and associates reviewed Manning and colleagues' 1980 and 1981 published studies.65 The derived ROC curve indicated that no specific cutoff point for the absence of fetal asphyxia existed. Thus, any arbitrary cutoff point would miss some asphyxiated fetuses unless the false-positive rate was allowed to be excessively high. Second, analysis of the ROC at Manning's own cutoff point for intervention showed that the NST and FB alone were as efficacious as the entire profile. The additional parameters (FM, FT, AFV) did not improve discriminatory strength. Manning and his group have now used the BPP to monitor more than 28,000 high-risk pregnancies. Richardson's ROC analysis has not been applied to this much larger number of tested pregnancies. It is therefore unknown if the original findings would be confirmed or altered. Vintzileos and collaborators also found high individual false-positive rates for the biophysical activities but improved predictive value for adverse outcome with combination testing.5 In this small study of 150 high-risk pregnancies, the BPP was more reliable than the CST in predicting fetal hypoxia at birth. Baskett and colleagues found increased predictability for perinatal death with the composite BPP score.101 Their prospective study analyzed the course of 4148 patients who had received a BPP within 1 week of delivery. In 1985, Manning and co-workers100 reviewed the use of the BPP in 12,620 consecutive patients with a live fetus at the inception of testing. The overall perinatal mortality rate was 7.4: 1000, of which 50% were stillbirths and 50% were neonatal deaths. During the study interval, within the same catchment region, the perinatal mortality rate for the general population was 14.3: 1000. Hence, a 50% decrease in perinatal mortality occurred in the tested population. Within the tested population, 75% of the perinatal deaths occurred as a direct result of either congenital malformation or severe Rh disease. Of the remaining 25% of perinatal deaths, 63% occurred as stillbirths. Unfortunately, most of these stillbirths occurred within 1 week of a normal BPP, in structurally normal fetuses. In contrast to the tested population, a much higher rate (90%) of structural normality was found among the perinatal deaths in the general population. Later, in 1987, Manning and co-workers reviewed the efficacy of BPP testing in 19,221 consecutive high-risk pregnancies .97 The rate of fetal death after a last normal test was 0.726:1000 (14 deaths). Two of the 14 fetuses died within 24 hours of a normal test. The mean interval between the last test and fetal death was 4.4 days. The corrected perinatal mortality rate was 5.06 : 1000, which was lower than that expected for their low risk population. The corrected perinatal mortality rate excluded deaths due to a major anomaly or due to red blood cell alloimmunization. |
BIOPHYSICAL PROFILE VERSUS NONSTRESS TEST AND CONTRACTION STRESS TEST | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
BPP testing results in fewer equivocal findings and a higher incidence of normal test results than either the NST or CST.3,72,100 Manning and colleagues found a significantly higher PPV for a low 5-minute Apgar score with the BPP than with the NST in their prospective blinded study comparing the BPP (in 375 patients) with the NST (in 360 patients). In a prospective randomized study, Platt and associates96 compared the NST (in 361 patients) with the BPP (in 279 patients). An improvement in predictability, but not a statistically significant one, occurred for the NPV, sensitivity, and specificity for predicting overall abnormal outcome. Abnormal outcome was defined as fetal distress in labor, 5-minute Apgar score less than 7, small-for-gestational-age infant, or perinatal mortality. The BPP did have a significantly higher PPV for an abnormal outcome, however. Eighty-eight percent of the pregnancies with abnormal BPP's had an abnormal outcome, compared with 33% with NR-NST's. Both Manning and Platt and their co-workers have shown that the use of the BPP can therefore reduce the number of false-positive NST's. Neither Manning's nor Platt's group found that either test was superior in predicting antenatal stillbirth.96,102 In a small study of 158 predominantly high-risk patients, Schifrin and associates used real-time ultrasonography after an NST to see if a modified BPP would increase the predictability of adverse perinatal outcome.55 The interval between testing time and delivery was not noted. Although normal test results highly predicted normal outcome, regardless of testing method, abnormal test results were poor indicators of poor outcome. However, they did find the modified BPP to be more reliable than the CST in predicting an abnormal fetus after a NR-NST. Table 5, Table 6, Table 7, Table 8, Table 9,describe the relative advantages and disadvantages of each antenatal testing method, as well as the statistical characteristics of each.3,68,71,79,97,100,101,103
TABLE 7. Oxytocin Challenge Test
TABLE 8. Incidence of Normal Studies
TABLE 9. Death Within 1 Week of Normal Test Result
|
CONCLUSION |
Antepartum management of high-risk pregnancies involves a balance of risks. Early delivery to minimize the morbidity and mortality associated with the high-risk condition may lead to severe morbidity or even mortality as a result of prematurity complications. Fetal surveillance tests have been developed to assess well-being at the time of the test and the statistical likelihood of future fetal well-being during a specified interval of time. The NST is widely used in this country for primary surveillance of fetal well-being in high-risk pregnancies. Although a reactive NST is an excellent predictor of fetal well-being, most NR-NST's are not associated with fetal compromise.3 In the recent past, the CST has been used as the follow-up test for NR-NSTs. Although CSTs are associated with a low false-negative rate,3 they are invasive and time-consuming, are contraindicated in certain conditions, require a hospital setting, and can precipitate premature labor or fetal distress. The BPP (with the NST) can usually be performed in less than 18 minutes in an efficient testing center.99 The BPP is noninvasive and has no contraindications. However, specialized equipment, space, and personnel are required for sonographic testing. Epidemiologically, when a disease has a low prevalence (i.e., perinatal mortality in this country), the false-negative rate of monitoring tests will be low regardless of the test's sensitivity or specificity. Additionally, the false-positive rate will be high unless the test is very specific (i.e., >99.5%).3 Both the NST and CST have high false-positive rates-greater than 50%.3 Because the NST and CST have insufficient diagnostic accuracy in regard to the abnormal fetus, multiple parameter measurement with a BPP was developed. Manning, Vintzileos, Schifrin, and Baskett and their groups each found increased positive predictability of adverse perinatal outcome when combination testing was performed.5,54,55,101 Manning and colleagues found that the perinatal mortality rate in the referred high-risk population was lower than that of the low-risk population of the same area.100 The exact contribution of BPP testing to this decrease is not known. Unfortunately, there are insufficient well-designed studies comparing the efficacy of the NST, CST, and BPP. Moreover, there will always be a small number of fetal and neonatal deaths that may not be predictable by any type of testing, such as those due to acute placental abruption, neonatal sepsis, or acute changes in maternal well-being. Additionally, more information about the relative importance of the individual BPP components is needed. Furthermore, Doppler surveillance of fetuses is increasing, although its role in assessing high-risk pregnancies is unclear at this time. It is hoped that all such efforts will help minimize perinatal morbidity and mortality for generations to come. |